Monitored equipment

sim-freezer-005

Device sim-pi-005 Last update 2026-08-12T16:25:10
EXCELLENT
Client overview

Equipment status

Live
Equipment Health
94.0 %
EXCELLENT

Critical degradation relative to the equipment baseline has been detected.

Risk level Very low 0%
Prediction No near-term warning
Recommended action Inspect sensor wiring, connectors, probe placement and acquisition electronics before diagnosing the refrigeration system. Based on the current analysis
Most likely cause Sensor or instrumentation fault 95.0%
Sentinel summary

Everything is working normally.

Cooling, electrical load and sensor readings match the usual behavior of this equipment.

Sentinel Brain

Why Sentinel reached this conclusion

Current assessment

Critical degradation relative to the equipment baseline has been detected.

Most likely cause Sensor or instrumentation fault
Confidence 95.0 %

One or more sensor signals are missing, frozen, implausible or changing too quickly to represent normal equipment behavior.

Health areas
Thermal 100.0%
Electrical 100.0%
Cooling 90.0%
Sensors 75.0% Sensor integrity score: 100% = no anomaly detected; a lower score reflects findings such as missing, implausible or unstable sensor data.

Technical findings

11
INFO 95.0%

INTERNAL TEMP STABLE

Internal temperature trend is stable.

-0.0037 °C/h
INFO 95.0%

INTERNAL TEMP STABILITY OK

Internal temperature variability remains within the provisional nominal range.

0.1899 °C
INFO 95.0%

COMPRESSOR TEMP STABLE

Compressor temperature trend is stable.

0.8854 °C/h
INFO 95.0%

COMPRESSOR CURRENT STABLE

Compressor current trend is stable.

-0.0007 A/h
INFO 95.0%

INTERNAL TEMP BASELINE OK

Internal temperature remains consistent with this equipment's baseline. Current average: -80.009 °C; baseline: -80.005 °C.

-0.0038 °C
INFO 95.0%

COMPRESSOR TEMP BASELINE OK

Compressor temperature remains consistent with this equipment's baseline. Current average: 57.505 °C; baseline: 52.862 °C.

4.6431 °C
INFO 95.0%

COMPRESSOR CURRENT BASELINE OK

Compressor current remains consistent with this equipment's baseline. Current average: 1.204 A; baseline: 1.208 A.

-0.0033 A
INFO 95.0%

EVAPORATOR DELTA BASELINE OK

The internal-to-evaporator temperature difference remains consistent with this equipment's baseline.

0.0 °C
INFO 92.0%

EVAPORATOR DELTA STABLE

Cooling temperature difference remains stable.

0.0 °C
MEDIUM 82.0%

COOLING EFFORT DRIFT

A moderate increase in compressor effort has been detected relative to this equipment's baseline.

4.6398 index
HIGH 90.0%

COMPRESSOR TEMPERATURE C IMPOSSIBLE JUMP

Compressor temperature sensor changed by 27.918 °C between two consecutive measurements. The provisional maximum accepted jump is 15.000 °C.

27.9176 °C
Real-time data

Current measurements

Internal -80.32093814356587 °C
Ambient 22.17363712921194 °C
Evaporator -86.32093814356587 °C
Compressor 69.30024033533573 °C
Current 1.117258096978358 A

Temperature history

Sentinel DNA

Normal behavior of this equipment

Learning
Normal internal temperature
Normal compressor temperature
Normal compressor current
Normal cooling difference
Average run time
Average rest time
Brain Memory

Health history

Learning
Stored diagnostics
First Health Score
Current Health Score
Health change

Health Score evolution

Brain timeline

Technical tools

Maintenance

Calibration

Record a comparison between a Sentinel sensor and a traceable reference.

Sensor health

Sensor integrity is evaluated by Sentinel Brain from recent real measurements.

Sensor score75/100
Open sensor findings
Diagnostics

Database integrity and local storage are checked directly on this Sentinel node.

SystemOK
measurement_database · ok monitoring_database · ok maintenance_database · ok disk_space · 34.37 GB free
Backup

Create a ZIP containing configuration, databases, code, templates, logs and tests.

Download full backup
Calibration history

Recorded reference comparisons

No calibration recorded for this equipment yet.
Alarm management

Alarms

No active alarms
Active alarms 0 Requires attention now
Awaiting acknowledgement 0 Waiting for a user response
Escalated 0 Sent to the next contact
Alarm history 0 Recorded alarm events
Current state

Everything is clear.

Sentinel has no active alarm for this equipment.

Escalation

Automatic notification chain

1
Primary contact Email / SMS
2
Acknowledgement Wait configured delay
3
Next contact If not acknowledged
Architecture ready Email, SMS, acknowledgement, delays, groups and escalation rules will use this page.
Recent alarms

Alarm events

No alarm has been recorded yet.